Chloride Lighting Inverters UL924 UPS
Chloride Power Electronics manufactures one of the reliable and dependable emergeny lighting inverters in the industry. Chloride lighting inverter is equiped with 90 minute battery back up and meets the UL 924 standards. Chloride lighting inverter ranges from 10 to 75 KVA with unity output power factor. All Chloride lighting inverters are three phase.
Low-Impedance Power Conditioning vs. Surge Suppression
Characteristics of Surge Suppression Technology
¥ Surge suppressors do not operate until their clamp voltage is exceeded (approximately 250 V on a 120 V system). Voltage disturbances lower than the clamp voltage can pass right through the suppressor into the equipment being protected.
¥ Surge suppressors offer no protection from disruptive high-frequency noise.
¥ By its very design, a surge suppressor can convert less damaging normal-mode disturbances to more damaging common-mode noise.
¥ Over time, a surge suppressor can fail, usually leaving the user with no indication that his equipment is unprotected.
¥ Specifications such as joule ratings and response time are typically used to characterize performance levels of surge suppressors. However, these specifications have little bearing on the level of protection provided.
Advantages of ONEAC Low-Impedance Power Conditioning Technology (Oneac Power Conditioner)
In comparison, the level of protection offered by low-impedance power conditioning is at least one order of magnitude larger than that offered by a surge suppression device. Ensuring reliable operation of critical equipment, ONEAC power conditioner virtually takes out all power disturbances without introduction of new power problems of its own.
¥ ONEAC UPS and ONEAC power conditioners virtually eliminate all possible disturbances, no matter what is their characteristics.
¥ ONEAC UPS and ONEAC power conditioners Provide round the clock power conditioning
¥ ONEAC UPS and ONEAC power conditioners are designed to eliminate disturbances, not just divert them, ONEAC power conditioners do not create destructive noise conversions.
¥ Provided with a five-year warranty, ONEAC medical grade power conditioners are designed to improve reliability and longevity of the connected electronics .
¥ The performance of ONEAC products is specified via let-through voltage Ñ the voltage that gets through when subjected to a standardized input transient Ñ fully defining the level of protection offered.
Common Asked Questions Regarding Surge Suppression
Q: This surge suppression device meets UL1449. Does the ONEAC power conditioning device?
A: UL1449 is a standard developed by Underwriters Laboratories (UL) to ensure the safety of a surge suppressor. It does include a surge test designed to determine whether a product will safely withstand (no flame, sparks, etc.) the types of surges it may be subjected to in the field. If the manufacturer so desires, he can have the surge test let-through voltage measured by UL. However, the mere statement that a product meets UL1449 has no bearing on the level of protection offered. ONEAC UPS and ONEAC power conditioners are classified by UL not as surge suppressors but as power supplies and therefore, are listed under the power supply standards Ñ UL1012 and UL1778.
®
Q: The light on the surge protector indicates it is providing protection, right?
A: Not necessarily. The fact that a surge suppressors light is illuminated does not mean it is actually providing protection. On some surge suppressors, the light may merely indicate that the suppressor is plugged in and the power is on. In reality, the device may have failed, providing absolutely no protection to the load. In contrast, ONEAC UPS and ONEAC power conditioners constantly provide power conditioning to the load, even when the power is turned off.
Q: ONEAC states that surge suppressors fail. Why then, does ONEAC employ Metal Oxide Varistors (MOV) in its products?
A: Properly utilized surge suppressors are useful as integral components of a power conditioning device.
ONEAC UPS and ONEAC power conditioners employ surge suppressors in its power conditioning products as a first line of defense to extremely severe transients, such as lightning. Also, the failure rate of an MOV is directly related to the number of times the device operates or fires. For example, an MOV that is designed to clamp at 250 V will fire far more often than one designed to clamp at 1500 V. This causes the one that clamps at 250 V to have a much shorter lifetime. The suppressors employed in ONEAC UPS and ONEAC power conditioners operate only when subjected to these extremely severe (and extremely rare) disturbances.
System Availability
System availability is a measurement of how many hours a year the system is available to the users. The same applies to power. Power is most important component when the calculate system availability. By far power is the largest reason for computer downtime. Thus the IT managers by increasing power reliability they automatically increase the system availability.
By increasing MTBF (mean time between failures) and reducing MTTR (mean time between repairs) of the individual components in critical power distribution system such as MGE Uninterruptible Power Supply or as some may say APC Uninteruptable Power Supply (UPS), PDI Power Distribution Unit (PDU), Static Transfer Switch (STS) the over all power availability will increase. It is not just the IT world that is concerned with power availability and reliability but more critical medical industry is consumed by it. The Medical Grade Power Supply and online UPS medical grade have made a significant improvement in medical power reliability. The MTBF can me improved by two ways, one, increase the reliability of individual components of equipment, two, increase the redundancy. There is a limit to increasing the reliability of components because everything will fail at some point in time. The estimated MTBF for most components range between 50,000 and 200,000 hours.
In comparison MTBF can be improved three to six times by adding redundancy to the system. This can be done by doubling Uninterruptible Power Supply or Uninteruptable Power Supply (UPS), Twinsource Static Transfer Switch (STS) and Power Distribution Unit (PDU). Same could be said about online UPS medical grade and Medical Grade Power Supply. In reality we can maximize our cost by achieving optimum reliability by specifying very reliable but not prohibitive in cost components with a redundant configuration. Chloride, MGE, Powerware and APC over the years has strived to achieve highly reliable UPS by doing both.
Reducing MTTR is achieved by easily swappable components. It would be best it this could be accomplished while the equipment were hot therefore hot-swappable. This would be most useful since the redundant failed component can be replaced while the system is still operational. To some degree Chloride, APC, Powerware, Twinsource, PDI, and MGE have achieved this task to varying degrees. One must study the different designs in detail to make sure that it meets their needs and requirements. The (UPS) Uninterruptible Power Supply or Uninteruptable Power Supply (UPS) industry has made a great effort in achieving higher system reliability. Let it be said that this is true for the online UPS medical grade and Medical Grade Power Supply industry as well.
The IT and facility personnel must choose their own best compromise between availability and cost. This choice is some times rated by power availability index (PA). A single UPS and PDU at a lower cost has a PA-1 rating. This system has a limited reliability due to the reliability of its least reliable component. Even though a redundant UPS and PDU system with PA-2 rating has better system reliability the repairs could be lengthy and expensive with major downtime implications.
The PA-3 rated modular UPS offers same high availability level with multiple hot-swappable components and redundant batteries. This will eliminate the downtime requirement for servicing.
Clean reliable power is at the heart of all business electronic processes (Data Sheet)
Without clean and reliable electrical power critical data stop to be created, stored and transmitted. This maybe considered an inconvenience to an individual but it can totally halt all business transactions and have drastic effects on the bottom line. Xtreme Power Conversion Corporation a manufacturer of business enterprise ups is the fastest growing power protection company. They specialize in providing data protection solutions for small to medium businesses. Their Xtreme Performance Rack/Tower Enterprise UPS is designed and manufactured based on the premises of max reliability, low ownership cost, enterprise features and unmatched prices.
XPRT Xtreme Performance Enterprise UPS (Uninterruptible Power Supply) eliminates the questions about physical form factor with ability to rack mount, tower mount and wall mount all in a slim 2U high enclosure. The customer will be assured that this Enterprise UPS (Uninterruptible Power Supply) will fit anywhere.
XPRT Xtreme Performance Enterprise UPS (Uninterruptible Power Supply) are available in four sizes (1000VA, 1500VA, 2000VA, and 3000VA).
XPRT Xtreme Performance Enterprise UPS (Uninterruptible Power Supply) are the perfect selection for critical business enterprise servers, point of sales electronic equipment, telephone and data communication networks. Industry class enterprise level features and world leading prices enable the XPRT Xtreme Performance Enterprise UPS (Uninterruptible Power Supply) best power quality choice for all business applications needing max power reliability and uptime
XPRT Enterprise UPS features:
True OnLine double conversion technology
XPRT Enterprise UPS (Uninterruptible Power Supply) provides max compatibility with all connected load
Maximize Space
XPRT Enterprise UPS (Uninterruptible Power Supply) only occupies 2U rack space
Enterprise grade LCD display
XPRT Enterprise UPS (Uninterruptible Power Supply) monitors and displays precisely measured parameters on the front panel LCD display
Scalable battery runtime
XPRT Enterprise UPS (Uninterruptible Power Supply) provides ability to add battery modules as your runtime needs increase
Flexible form factors
You may install the XPRT Enterprise UPS (Uninterruptible Power Supply) in a tower, rack- mount or wall-mount configuration to meet the site requirements
Quick battery charge time
XPRT Enterprise UPS (Uninterruptible Power Supply) has the ability to charge the batteries to 90% runtime capacity in 4 hours
Communication interface capabilities
The SNMP network interface, RS232 and USB port are available on XPRT Enterprise UPS (Uninterruptible Power Supply)
Emergency Power Off Switch (EPO)
Is a safety feature that is available on XPRT Enterprise UPS (Uninterruptible Power Supply) that is typically available of larger units
Load shedding capability
This feature enables the XPRT Enterprise UPS (Uninterruptible Power Supply) to maximize battery back up time for more critical servers and electronics
Quite and efficient operation
The cooling fans on the XPRT Enterprise UPS (Uninterruptible Power Supply) are designed with speed control to consume less power and operate quietly
Enterprise grade software
XPRT Enterprise UPS (Uninterruptible Power Supply) comes with easy to install connectivity software
Network data surge suppression
XPRT Enterprise UPS (Uninterruptible Power Supply) comes with one in one out RJ45 surge protection to provide data integrity in case of conducted noise
CHLORIDE
POWER PROTECTION
Product Description and Specification
US Guide Specification for Model 90NET
180-500kVA
Three Phase
Uninterruptible Power Supply
Rev. 08/06
A. This Specification defines the electrical and mechanical characteristics and requirements for a continuous duty; three-phase, uninterruptible power system, hereafter referred to as the ENTERPRISE UPS. The ENTERPRISE UPS shall operate with the building supply to provide conditioned power as well as power back up for the critical loads.
A. The ENTERPRISE UPS shall be designed in accordance with the applicable sections of the current revision of the following documents. Where conflict arises between these documents and statements made herein, the statements in this specification shall prevail.
The ENTERPRISE UPS shall be listed to UL1778 by ETL.
A. The ENTERPRISE UPS shall be a true double conversion, “On-Line” system consisting of the following major components:
A. The ENTERPRISE UPS shall be designed to operate as an on-line, reverse transfer system in the following modes:
B. Future Expansion: Up to 8 modules can be paralleled as required to support future growth.
1.5 ENVIRONMENTAL REQUIREMENTS
A. The System shall withstand any combination of the following external environmental conditions without operational degradation.
A. The manufacturer shall have a minimum of 25 years experience in the design, manufacture, and testing of solid-state transistorized ENTERPRISE UPS systems of similar capacity.
The ENTERPRISE UPS unit, comprised of the rectifier, charger, inverter, static transfer switch STS, and maintenance bypass shall be housed in a single, free standing NEMA type 1 enclosure. Cabinet doors and covers shall be removable for expedient servicing, adjustments, and installation. The ENTERPRISE UPS cabinet shall be structurally adequate and have provisions for forklift handling. The cabinet shall be front access only for service with top access for fans.
Recently APG UPS and ENTERPRISE UPS (uninterruptible power supply) inventory has been increased to meet the demand for medical grade power supply with backup battery.
APG group power supply meets the industry standards for online ENTERPRISE UPS medical grade applications.
APG UPS and ENTERPRISE UPS power supply is most reliable in the industry.
APG (Applied Power Group) is supplier of critical power distribution equipment such as online ENTERPRISE UPS medical grade and medical grade power supply with backup battery and uninteruptable power supply.
Many people in the industry ask us what is APG UPS and ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY)? APG UPS and APG ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY) is a very reliable medical grade power supply with backup battery.
We recommend the use of APG UPS (UNINTERRUPTIBLE POWER SUPPLY) AND ENTERPRISE UPS or online ENTERPRISE UPS medical grade power supply over an uninteruptable power supply in critical patient related monitoring devices.
APG UPS (UNINTERRUPTIBLE POWER SUPPLY) AND ENTERPRISE UPS is well respected in the arena of supplier of critical power systems.
At APG we are proud to provide the very best online ENTERPRISE UPS medical grade and medical grade power supply with backup battery and uninteruptable power supply.
All materials and components making up the APG UPS (UNINTERRUPTIBLE POWER SUPPLY) AND ENTERPRISE UPS shall be new, of current manufacture, and shall not have been in prior service except as required during factory testing. All bus bars shall be copper.
Redundant, forced air-cooling shall be provided to ensure that all APG UPS (UNINTERRUPTIBLE POWER SUPPLY) and enterprise ups power supply components are operated within specification with air entry at the front and exit at the top. Optional external battery cabinets will be convection cooled.
The ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY) and apg ups power supply shall be constructed of replaceable subassemblies. Printed circuit assemblies shall be plug-in. The main control printed circuit boards shall be interchangeable across the entire product range.
The rectifier section of medical grade power supply with backup battery shall be a six-pulse, solid-state device. It shall be capable of receiving utility input and rectifying it to produce Direct Current (DC) power at levels sufficient enough to supply the load via the inverter and charge the batteries.
2.2.1.1 Input Protection: The rectifier of medical grade power supply with backup battery shall include protection against primary power surges, (except for lightning transients) and under or over voltage conditions. This protection is provided via fuses, Circuit Breakers, and Microprocessor Control of the rectifier.
2.2.1.2 Filtering: Sufficient filtering of the rectifier/charger output shall be provided to prevent damage to the battery. Ripple voltage shall not exceed ≤2% RMS.
2.2.1.3 applied power group In-Rush Limiting: When the primary power of medical grade power supply with backup battery is applied to the rectifier, the current surge shall be limited to no more than nominal input current when the ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY) is operating at 480VAC input.
2.2.1.4 applied power group Power Walk-In: When the utility power is applied to the rectifier, the current shall be <25% of the full load current and shall gradually increase to full load rating within 10 seconds (adjustable 1-90 sec.).
2.2.1.5 applied power group Automatic Restart: Upon restoration of utility AC power after a power outage, the apg ups power supply rectifier shall automatically restart and assume the inverter and battery recharge loads.
An integral charging circuit of APG UPS (UNINTERRUPTIBLE POWER SUPPLY) and enterprise ups power supply shall be capable of recharging the batteries during normal operation to ensure maximum life from the battery system.
2.2.1.6.1 applied power group Charger Capacity: The charger of apg enterprise ups power supply shall have sufficient capacity to recharge a fully discharged battery to 90% capacity within ten times discharge time.
2.2.1.6.2 Battery Test: The APG UPS (UNINTERRUPTIBLE POWER SUPPLY) and enterprise ups power supply shall periodically check the battery system for an open cell. If the ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY) detects an open cell, an alarm condition shall be displayed and an audible alarm shall sound.
The inverter section of the APG UPS (UNINTERRUPTIBLE POWER SUPPLY) and enterprise ups power supply converter module shall utilize Insulated Gate Bipolar Transistors (IGBT's). This solid-state device that incorporates digital signal processing (DSP) pulse width modulation (PWM) technology is capable of accepting the output of the rectifier or the battery system voltage and delivering apg group power supply within specified limits to the critical load bus. The inverter shall be microprocessor controlled and include all necessary timing logic and control circuits to accommodate an apg group power supply.
2.2.2.1 applied power group Inverter Start-Up: The APG UPS (UNINTERRUPTIBLE POWER SUPPLY) and enterprise ups power supply inverter shall automatically startup when a start command is generated and shall be stable and ready to deliver power to the load within 2 seconds.
2.2.2.2 applied power group Inverter Protection: APG UPS (UNINTERRUPTIBLE POWER SUPPLY) and enterprise ups power supply Inverter IGBT's shall be protected by current limiting circuits. The inverter of the apg group power supply shall be capable of running indefinitely with the batteries disconnected. For rapid removal of the apg group power supply from the critical load, the inverter’s control electronics shall instantaneously turn off the inverter when the inverter’s capacity is exceeded. Simultaneously, the static transfer switch STS shall transfer the load to apg group power supply without interruption to maintain continuous power to the critical load.
2.2.2.3 applied power group Inverter Oscillator: The APG UPS (UNINTERRUPTIBLE POWER SUPPLY) and enterprise ups power supply inverter shall contain an oscillator capable of operating and maintaining the output frequency of the inverter within specified limits. The inverter oscillator shall be capable of frequency synchronization and phase locking to the bypass utility power source frequency. When apg group power supply is operating as a slave to the utility power and a failure occurs in the slaving signal, the inverter oscillator shall automatically revert to a free running state and maintain the specified limits. The oscillator shall not drift more than 0.05% while operating at maximum rated operating temperature. This is a critical aspect of a apg group power supply
The ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY) shall be designed to utilize Valve Regulated Lead-Acid (VRLA) or Wet Cell (240 cell) & NiCd (375 cell) batteries.
Bypass switching shall allow the critical load to be fed from the bypass power source, while providing isolation of the static switch STS during maintenance.
Input:
a. Nominal Voltage: 480 VAC, 3 Phase, 3-wire (plus ground)
b. Voltage Limit: +15/-10% from nominal voltage during battery recharge; +15/-20% with fully charged battery
c. Frequency: ±5% (57 - 63 Hz)
d. Power Factor: > 0.9 at full load, nominal conditions.
Output:
a. Nominal Battery Voltage: 480 VDC
"Float " Operation: 2.27 VDC per cell @ 77oF
b. Regulation: ± 1% maximum for input voltage and DC current variations
c. Temperature Compensation: -0.11% of float volts per °C
d. Ripple Voltage: Less than 2% RMS voltage, with inverter fully loaded and battery disconnected
e. Battery AC current ripple: <1% nominal
f. Protection: Electronic current limiting, input breaker and fuses.
2.3.2.1 Power Rating: APG UPS AND ENTERPRISE UPS (UNINTERUPTABLE POWER SUPPLY) output ratings are shown at 0.9 pf leading or lagging. Other power factor loads can be supported.
2.3.2.2 Input: Shall operate within specification over the nominal rectifier output range and minimum battery voltage of 1.65 volts per cell.
2.3.2.3 Output Voltage: 480/277, 60HZ, 3 Phase, 4-wire (plus ground)
2.3.2.4 Output Regulation:
Balanced Loads: ±1% balanced load - Phase Angle 120o ±1o
Unbalanced Loads: ±3% 100% unbalanced load - Phase Angle 120o ±2o
2.3.2.5 Output Waveform: Sinusoidal
2.3.2.6 Frequency Stability: Normally synchronized to utility line over frequency range of ± 1.5% or optionally ±0.75%, ±2.5%, ±6%; free running ±0.1%. Slew rate £1.0 Hz/Sec
2.3.2.7 Output Response: <± 8 (TBV) % maximum deviation for less than one cycle.
2.3.2.8 Overload Rating: 150% for 1 minute
125% for 10 minutes
2.3.2.9 Short Circuit Rating: 200% for 10ms, then
150% for 5 sec
2.3.2.10 Harmonic Content: Linear loads: Max. Voltage THD < 3%
2.3.2.11 Efficiency (DC-AC): Minimum - 94.5% at Full Load.
(AC-AC): Minimum – 93% at Float
2.3.3.1 Input: 480VAC, 60HZ, 3 Phase, 4-wire (plus ground), or 480VAC, 60Hz, 3-phase, 3-wire (plus ground)
2.3.3.2 Power Rating: Static switch STS is continuous duty power rated.
2.3.3.3 Transfer Characteristics:
Transfer time from inverter: The transfer to static bypass of an online enterprise ups medical grade is needed when the bypass source is in phase with the inverter shall be make-before-break.
Transfer time from inverter to utility when both sources are not in phase lock: 20 ms (To prevent damage by phase reversal to the load.)
2.3.3.4 Voltage Limits: ±10% of nominal input voltage for online enterprise ups medical grade is more than enough.
2.3.3.5 Frequency Tolerance: Tolerance shall be set for a frequency range of ± 1.5% or optionally ±.75%, ±2.5%, ±6%
2.4.1 Front Panel Display
The ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY) shall incorporate a Front Panel Display consisting of a backlit LCD Display of 8 lines by 21 characters. This LCD shall display APG UPS AND ENTERPRISE UPS (UNINTERUPTABLE POWER SUPPLY) and Battery status, metering, and active alarms. This LCD shall also show a mimic diagram highlighting the current operating status of the ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY).
2.4.2 Control Panel Indicators
A. System Normal: This shall indicate that the APG UPS AND ENTERPRISE UPS (UNINTERUPTABLE POWER SUPPLY) is running in normal operation.
B. Warning: This shall indicate that the ENTERPRISE UPS has detected an anomalous condition external the APG UPS AND ENTERPRISE UPS (UNINTERUPTABLE POWER SUPPLY) that could affect its normal operation.
C. Alarm: This shall indicate that the online enterprise ups medical grade UPS (UNINTERRUPTIBLE POWER SUPPLY) has an internal alarm condition.
2.4.3 Panel Controls
2.5.1 Interface Cards
An external bypass shall be available to allow the entire APG UPS AND ENTERPRISE UPS (UNINTERUPTABLE POWER SUPPLY) system to be bypassed for service without requiring the load to be shut down.
A separate alarm unit shall be provided and shall include at least the following monitoring and alarm functions:
An apg group power supply software package shall provide for safe system shutdown and useful power management. Available features shall include network shutdown, scheduled shutdown and restart, event messaging, event logging, data logging, real-time viewing, APG UPS AND ENTERPRISE UPS (UNINTERUPTABLE POWER SUPPLY) diagnostics, and remote access. This option which is provided by supplier of critical power equipment requires a customer supplied computer and meet the following operating system requirements. This feature also depends on how many medical grade power supply with backup battery are present at the site. The doctors at hospital rely on online ups medical grade capabilities.
2.5.6 Parallel Operation by supplier of critical power equipment
Up to eight (8) modules of the APG UPS AND ENTERPRISE UPS (UNINTERUPTABLE POWER SUPPLY) shall be capable of working together in parallel operation for either redundancy or capacity when a paralleling option board is installed in each module.
The following procedures shall be performed by Chloride who is Authorized supplier of critical power equipment during the Factory Start-Up Service:
The supplier of critical power equipment shall have available a nationwide field service organization staffed by factory trained Field Service Engineers dedicated to the start-up, maintenance and repair of ENTERPRISE UPS (UNINTERRUPTIBLE POWER SUPPLY) equipment. The manufacturer shall have a toll free service telephone number answered 24 hours a day / 365 days a year.
| Medical Power Conditioner: 120 to 3000 VA | ||
| Medical Grade UPS 300 - 600VA | ||
| Three Phase DC to AC Inverter 20 - 40 KVA | ||
| Single Phase DC to AC Inverter 10 - 10 KVA |
![]() |
||
| Rack Mounted Static Transfer Switch | ||
| Rack Mounted Maglatch Transfer Switch | ||
| Upgrade to 8x9 rreliability | ||
![]() |
||
| Dry type transformers | ||
| Dry type and liquid filled substation | ||
| Dry type and liquid filled drives isolation | ||